NOT KNOWN DETAILS ABOUT AUTOMATIC SAMPLE CHANGER

Not known Details About automatic sample changer

Not known Details About automatic sample changer

Blog Article

Download Datasheet Founded in 1987, ANTECH is surely an impartial company of customized equipment, measurement companies and technological know-how on the nuclear marketplace.

Automate weighing as part of your lab for Improved throughput and security: powder and liquid dispensing, capsule filling, filter weighing and much more.

Ought to a jam occur through the travel of your elevator cage sixty two from its uppermost place illustrated in solid traces to its lowermost place illustrated in phantom, the subsequent motion requires put.

Reduced-track record sample changer for automated gamma spectroscopy in counting laboratories at nuclear and investigation services.

Last but not least, reference is directed to FIG. 10, which happens to be a block diagram on the jam alarm circuit employed while in the inventive automatic sample changer. If the elevator motor is idle, a good voltage changeover appears at junction 210. This constructive transition is shaped right into a pulse by the pulse differentiator 212, and passes in the Typically shut microswitch designated at 124 in FIG.

includes 100mm (four″) thick guide shielding cylinder, lined with tin and copper. A series of split stepped foundation plugs let for different sized HPGe detectors to be mounted during the process simply without any shine route into the detector. A Chamber Lid made from 100mm (4″) thick direct shielding cylinder, lined with tin and copper, mounted inside of a plate aluminium housing is positioned on rails above the measurement chamber, and is also automatically opened and shut applying an actuator during the measurement method.

27. The sample changer recited in assert 26, and further more comprising: very first and next Restrict swap means for indicating, respectively, the orientation of mentioned motor signifies plus the posture of said elevator indicates when inside the uppermost and lowermost positions; and indicator signifies for indicating a jam in claimed elevator suggests when claimed to start with and next Restrict change suggests fall short to concurrently point out the uppermost or lowermost positions of reported control arm.

Automatic sample identification and simplified knowledge entry Bar code reader (Laser Class II) for automatic sample identification accessible to avert user faults Strategy assignment with bar code reader for easy Procedure without having manual system variety Enter the sample list by means of a bar code reader, touchscreen, or keyboard to simplify documentation and prevent glitches Develop preconfigured sample lists for your each day use to prevent monotonous knowledge entry responsibilities. You can save and cargo preconfigured sample lists. ”

HT1000I website provides simple setup and Procedure: for line priming, close-of-session washes and set up it characteristics an integrated keypad, even though for sample processing it might be controlled by the most well-liked ICP and Atomic Absorption application.

-lets the fully automated measurement of as many as 32 samples in a single work cycle. The positioning on the measuring cups, the measuring course of action, such as information recording and subsequent cleaning with the measuring bob, are fully automatic.

35. To be used in an automatic sample changer for transporting a plurality of check samples from a first area into a 2nd area, a constant elongated monitor which right encounters explained 1st locale at a person situation alongside its size; a plurality of impartial transport indicates sequentially positioned along significantly your complete duration of claimed observe, Just about every of which is customized to associate with a sample; and indexing means for associating with said plurality of transportation suggests to advance the samples connected therewith along said continual observe, mentioned indexing implies comprising a rotatable hub having a plurality of extensions thereon, Each individual of which extensions contacts and moves a plurality of mentioned transportation means at spaced areas together said monitor.

six. The sample changer recited in declare five, whereby each of stated transport signifies is in the shape of the puck aquiring a groove into the perimeter thereof; and wherein stated pucks slide in explained ongoing slot by Affiliation with their respective grooves.

33. The sample changer recited in claim 32, whereby stated a few detents are in the straight line; wherein a jam in claimed elevator implies results in explained plunger breaking far from the intermediate of reported 3 detents; and whereby the outer two of mentioned a few detents associate with reported plunger to reset explained breakaway connection following the jam continues to be corrected.

The AT-seven hundred automatic titrator supplies operators a range of decisions such as the usage of an built-in mini sample changer.  The mini sample changer can delay to six samples.  The look utilizes a rotating arm that holds the electrode(s), dispensing nozzle(s), and propeller stirrer previously mentioned Every single sample and maneuvers from sample to sample.

Report this page